Page 28 - PCC14
P. 28

 Systematic Review: Catheter Tip Placement
• Fair evidence (grade B) that ET catheter tip placement affects PR
• Fair evidence (grade B) that catheter tip placement in upper or middle uterine cavity (>1 cm from fundus) improves PR
 Systematic Review: Time Interval for Withdrawing Catheter after Embryo Plunging
• Fair evidence (grade B) to recommend immediate withdrawal of ET catheter after embryo expulsion (i.e. no difference a vs. 30‐ 60 second delay)
 Page 21 of 69
  28